DPI620G | Modular Multifunction Calibrator

Druck’s DPI620G series is an advanced, modular multi-function calibrator and optional HART/Foundation Fieldbus communicator with world-class pressure measurement and generation. Building on over half a century of market leading pressure expertise, the DPI620G is at the pinnacle of modular, portable calibrator offering and is at the heart of the Genii Advanced Modular Calibration System. With ATEX, IECEx and ETL approved intrinsically safe versions available for use in hazardous areas, the DPI620G platform is the preferred choice for countless operators across the globe. The DPI620G provides simultaneous measurement and source capabilities for the setup, testing and calibration of most types of process instruments including transmitters, transducers, gauges/indicators, switches, proximity detectors, counters, RTDs, thermocouples and valve positioners.

Description

Features

  • 14x safe area and 5x hazardous area models to satisfy budget and application requirements from a basic, electrical calibrator to a multifunction calibrator with HART, Profi Bus and Fieldbus.
  • Can be used with pressure modules and a module carrier or a pressure base station.
  • High resolution touch display and UI supporting gestures and swipes for a flatter menu structure and greater ease of use.
  • HART and Foundation Fieldbus digital communication with complete device description libraries, internal modems and free of charge upgrades.
  • Autonomous calibration wizard to store procedures and calibration data
  • Data log up to six channels simultaneously.
  • Provided with one Freemium 4Sight2 calibration software license.

Industries

Space

For more than decades, Druck has been supplying pressure measurement solutions to space programs worldwide. Our flight-qualified sensors are trusted in launch vehicles, satellites, and crewed spacecraft, delivering accuracy under the extremes of vibratio…

Oil & Gas

In the oil and gas industries, reliability, precision and stability are crucial for ensuring safe and efficient operations. Druck has been a trusted provider of high-performance pressure sensors for over decades, delivering innovative solutions that meet…

Medical

Accurate pressure measurements improve diagnosis and treatment and can enhance patient safety through reduced risk of misdiagnosis. Accurate measurements also allow for better monitoring of conditions and optimize the use of medical devices such as venti…

Industrial

Overcoming challenges with precision and reliability Industrial operations rely on accurate and reliable pressure measurement to ensure safety, efficiency, and productivity. Druck, delivers high-performance pressure sensors and instruments that meet the …

Automotive

Druck, manufactures pressure sensors that are built for accuracy and precision. We are one of the leading technologies in the world of industrial testing. When it comes to data gathering in industrial applications, there are three key areas to consider: …

Applications

Electrical Measurement

Measure, test and calibrate electric settings and loops in industrial control systems with Druck portable instruments.

FAQs

Data cannot be logged in Standby mode – the processor is effectively put to sleep.
While Data Logging if you press the power button to go to the Power Down menu.

We currently have Genii DPI620G units which we are regularly seeing CJ temperature As Found results out of specification @±0.2°C. We have to raise a deviation investigation into each and every failure because these units are calibration standards and have been found to be out of specification against the published Technical Data
Datasheet.

However, the ±0.2°C is only quoted in the documentation as an uncertainty specification and we are enquiring whether this is a realistic specification when accounting for annual drift between calibrations.

Yes, it’s at the Software Revision DK420 V03.20.01
The list is the same for the DPI620G / DPI620G-IS as the FF device list is part of the Main Application DK420.

The Foundation Fieldbus and Profibus DD Libraries are part of the instruments Main Application (software DK0420). Upgrading to the latest version of DPI 620 Genii software
will ensure you have the latest DD Libraries.

The DD’s on the manufacturers website are not in the correct format for the DPI 620G therefore cannot be directly added.
If there are any DD’s that are not in the current library then the you will need to provide us with the DD for us to format, we can then supply the procedure to add it to the
library

It is possible to upgrade Genii Lites to have HART and FF communication.
The instruments will require returning to the factory for reprogramming, the FF option also requires some hardware adding and the FF Licence Installing.
The instrument label will also require updating to reflect the model change.

Our Customer Care team can provide you with a price for the upgrade.

Using the internal supply of the Genii-IS to power the current source you would be limited to a maximum resistance of around 525 ohms at 24 mA.

If the PM620 is working, but isn’t been recognized by the DPI620GENII-IS when connected to the pressure base.

Then this could be due to signal or 5Vdc missing from the
terminal. Check across the terminals for signals, power the DPI620GENII-IS on and you can then measure the 5V dc at the two outer terminals. With instrument switched off you should see between the two middle terminals resistance approximately 9.36K ohms.
If no voltage or resistance then it could be that either base or digital board that is faulty and would need further investigation.

 

The glass is part of the touchscreen, therefore the touchscreen will have to be replaced.
The part number for the touchscreen is IS620-7.

It is possible to copy the cal data over so long as you can retrieve the cal data from the old digital board.
The procedure is described below:-
Note – It will be easier to follow the procedure if you plug a mouse into the Genii’s USB port.
From the Dashboard select the Applications icon, then select the Desktop icon.
From the Desktop select My Device -> MMC Memory -> AMC -> CFiles
Copy the following files to the instruments SD card (My Device -> SD Memory).
User Settings
Config
In turn delete each of the above files from the Digital Board and then copy the old file from the SD card to the CFiles Folder.
Once completed all ranges should display in white digits, any ranges showing blue digits will indicate an un-calibrated range.
Carryout a calibration verification to confirm that the data has been successfully transferred.
If you need to re-enter the serial number then from the menu select Calibration and enter the pin 1129, the serial number can then be entered.

The error message is likely to be caused by a hardware issue.
The instrument will need to be returned for investigation/repair

 

The HART Library needs to be installed on the instruments SD card and not the internal memory.
There are two methods to upgrade the HART Library:-

1. Using the upgrade procedure in the User Manual K0541 Issue 2 – First ensure that the instruments USB Client Port is set to Storage Mode. Access the USB CLIENT PORT setting
as shown below and ensure that the USB CLIENT PORT is set to Storage mode and not Communications.
Connect the USB lead from the PC to the Mini Type B USB port on the instrument.
The Internal SD card should then be seen on the PC as a removable disk.
The HART Library zip file can then be extracted to the SD card.
2. An alternative method to upgrade the HART Library would be to remove the battery from the instrument and then remove the SD card from its carrier within the battery
compartment. Plug the SD card into the PC or a card reader. Extract the HART Library zip file to the PC and then copy the HCF folder to the SD card (Note – remove the existing
HCF folder first).

Refit the SD card to its carrier and then re-fit the battery to the instrument. On power up the revision of HART Library should be shown in the Software Status menu.

Downloads

File type
TypeTitleLanguageFormatDownload
DatasheetsDruck DPI620G Genii DatasheetEnglishPDFDownload
User ManualsDruck DPI620G Genii Quick Start Guide K0542MultilingualPDFDownload
User ManualsDruck IO620-IDT622 Instrument Dirt Trap Instruction Manual K0505MultilingualPDFDownload
User ManualsDruck IDT600 Instruction Manual K0318MultilingualPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual K0541EnglishPDFDownload
User ManualsDruck IO620-CHARGER Instruction Manual K0455EnglishPDFDownload
User ManualsDruck IO620-IDT621 Instrument Dirt Trap Instruction Manual K0487EnglishPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KC0541ChinesePDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KD0541GermanPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KE0541SpanishPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KF0541FrenchPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KI0541ItalianPDFDownload
User ManualsDruck DPI620 Genii Instruction Manual KJ0541JapanesePDFDownload
User ManualsDruck DPI620G Genii Instruction Manual KK0541KoreanPDFDownload
User ManualsDruck DPI620G Genii Instruction Manual KP0541PortuguesePDFDownload
User ManualsDruck DPI620G Genii Instruction Manual KRU0541RussianPDFDownload
CertificatesDruck DPI620G-IS Certificates 116M7874MultilingualPDFDownload
FlierDruck DPI620G B Product FlyerEnglishPDFDownload
FlierDruck DPI620G H Product FlyerEnglishPDFDownload
Quick start & safety guideDruck DPI620G IS Quick Start and Safety Guide 114M5004MultilingualPDFDownload
Quick start & safety guideDruck RTD Interface Quick Start Safety Manual 139M2534MultilingualPDFDownload
Quick start & safety guideDruck DPI620PC Quick Start Guide 144M5990EnglishPDFDownload
Quick start & safety guideDruck DPI620G IS Quick Start and Safety Guide 172M9094KoreanPDFDownload

Contact us

A Druck expert is ready to listen by email, contact form and phone.

[email protected]

USA & Canada: +1 346 330 1150
France: +33 562 888 250
China: +86 800 9159 966