PACE Tallis – 传递标准校验仪

PACE Tallis

Druck 全新传递标准校验仪,利用 TERPS 性能实现市场领先的精度和长期稳定性。 不相信我们?阅读我们的公开信以了解更多信息。

描述

PACE Tallis 经过工程设计,具有多功能性,可在各种环境条件和测试介质中保持性能,提供低至 10 ppm FS 的精度。PACE Tallis 的便携性意味着现在可以对偏远、非理想位置进行校准,且由于装置结构坚固,降低了运输过程中的损坏风险。

PACE Tallis 设置和操作简便,与活塞式压力计相比,其作为传递标准的持有成本更低。它是校准实验室的理想选择,具有高达 15 ppm FS/年的长期稳定性,且仅需极少的维护。

行业

航天

30 多年来,Druck 一直为全球航天项目提供压力测量解决方案。我们符合飞行标准的传感器在运载火箭、卫星和载人航天器中备受信任,在极端振动、热循环和真空条件下提供精度。**来自网站的文本 ** 30 多年来一直提供用于航天应用的压力传感器 30 多年来,Druck 一直为航天工业提供压力测量解决方案,并提供专门设计用于承受恶劣环境同时保持最高精度和可靠性的产品。无论是航天器还是地面发射系统,到车辆组装和维护需求,Druck 都有完美的压力解决方案。 凭借我们在航空航天制造、验证与确认以及研发方面的传承…

核能

在核能行业,精准度和可靠性对于确保安全和效率至关重要。Druck 已确立了自己在压力传感技术领域的领导地位,提供的解决方案能够满足核能应用的严苛需求。 核能应用。 Druck 压力传感器用于核能领域的几个关键应用。它们在监测反应堆冷却剂系统中发挥着至关重要作用,确保压力和液位维持在安全限值内,以防止过热和潜在故障。此外,这些传感器还用于蒸汽发生器以监测蒸汽压力,这对于高效发电至关重要。

发电

In the dynamic and demanding power generation market, precision and reliability are paramount. Druck has been at the forefront of pressure sensing technology for over 50 years, providing innovative solutions that ensure optimal performance and safety in …

制药

Druck 产品帮助制药行业在药品生产过程中保持一致的条件,确保每批产品都符合要求的质量标准。这对于药品的有效性和安全性至关重要。此外,我们还帮助防止污染、提高工艺效率、监测关键参数并支持符合监管要求的自动化。 应用 洁净室传感器和仪表校准 温度校准 气压测量 制药工艺校准 开放配置选项

Medical

Accurate pressure measurements improve diagnosis and treatment and can enhance patient safety through reduced risk of misdiagnosis. Accurate measurements also allow for better monitoring of conditions and optimize the use of medical devices such as venti…

应用

压力校准和压力测试

视频

FAQs

The display update rate is 2 Hz.

However if you use the Maximum/Minimum Monitor to detect the Maximum pressure then the Scan Rate can be increased to give 10Hz.

The rear case of the DPI 104IS is not available as a spare part.
Special tooling is required to fit the pressure sensor into the case, we do not offer a repair service on the DPI 104IS.

With the scaling factor set to 1, the Voltage Output will be 0V to 5V corresponding to 0 to Full scale Pressure.
The accuracy of Voltage Output is 0.1% FS above 50mV, below 50mV no accuracy is specified.

The sensor to PCB cable is available as a spare part, the part number is IS104-2.

The instrument has detected an error at start up. First try resetting (restoring) the instrument by holding down all four buttons until the instrument goes off, the instrument will then restart.
If this does not cure the problem then check the transducer lead for bad connections or replace the lead if a spare one is available. If the transducer lead is OK then disconnect the battery for a few seconds and then re-connect it.
If the error is still present then the instrument will need to be returned/replaced.

You cannot switch over the mainboards as the mainboard contains all the calibration and temperature compensation data for the sensor, effectively the PCB and sensor are matched.

From the menu select the Tare function. Change the Tare function from “t off” to “t on” (leave the tA value set to zero), exit from the menu.

With the instrument displaying the pressure reading hold down the Enter key until “done” is displayed. The pressure reading
should now read zero.

The Quick Fit Adaptor is the same as the swivel connection on the PV62XG pressure bases, DPI 611 and DPI 612.

This allows the use of the IO620-HOSE’s and the IO620-BSP/NPT adaptors.

The remote gauge sensor is capable of measuring negative pressure but it is usually only calibrated in the Positive direction.
Negative Calibration is something we offer as an option on the DPI 705.
Below is what we state on the datasheet for Negative Calibration.
Please note there is no adjustment for the Negative direction, so accuracy is quoted as a percentage of the compound range. For a ±350 mbar sensor this would be a range of 700mbar.
Unless Negative Calibration is ordered at the time of manufacture there is no guarantee that the instrument will meet this specification as sometimes we need to select the sensor in order to meet the Negative specification.

For the DPI 705E it was recommended by our chief engineer to use the Autoclave 9/16 x 18 UNF connection on high pressure ranges (≥350 bar) due to the stress on the connection and to comply with the Pressure Equipment Directive (PED).
We do not supply adaptors for this connection as accessories with the DPI 705E, but we do supply an adaptor for the DPI 104 and PACE 1000 that have the same connection.
The adaptor used on the DPI 104 is a 9/16 x 18 UNF female to 3/8 BSP male, part number 182-190.
The adaptor used on the PACE 1000 is a 9/16 x 18 UNF female to 1/8 NPT female, part number IO-ADAPT-9/16AC.
If these are not suitable then alternatives are available from pressure fittings companies such as Swagelok, Parker, Staffordshire Hydraulics etc.

IMPORTANT NOTE: The PACE 1000 adapter IO-ADAPT-9/16AC has a pressure rating of 15000 psi / 1000 bar. Therefore the adapter is suitable for the DPI 705E internal ranges 350 bar/700 bar and external ranges 350 bar/700 bar/1000 bar but would it not be suitable for the external 1400 bar range.

The part numbers for the battery terminals with the pin pre-fitted are:
Positive Terminal IA2505-1-V0
Negative Terminal IA2505-2-V0

The display update rate is 2 Hz.

However for the DPI705 non IS version the same carry case is used for both instruments.

The carry case for the DPI 705E-IS is different to the carry case for the DPI 705-IS.

IO705B, carry case for the standard DPI 705 and IO705E-CASE, carry case for the standard DPI 705E both have the same internal part number.

The date stated on the calibration certificate is correct.

During manufacture the internal sensor of the DPI 705E is calibrated on a production calibration rig.
The sensors have an inhouse calibration period of 15 months and if unused will be recalibrated every 3 months.
This ensures that once fitted into a DPI 705E the calibration period will be at least 12 months when the instrument is shipped.
This is mentioned in section 3.1.4 of the user manual.

下载

文件类型
类型标题语言格式下载
DatasheetsDruck PACE Tallis DatasheetEnglishPDF下载
User ManualsDruck PACE SCPI Remote Communications Manual K0472EnglishPDF下载
Technical DocumentationDruck PACE Tallis: Is it as good as we say it is? | Open letterEnglishPDF下载
Calibration ManualDruck PACE Calibration Manual K0450EnglishPDF下载
Calibration ManualDruck PACE Calibration Manual KC0450ChinesePDF下载
Calibration ManualDruck PACE Calibration Manual KD0450GermanPDF下载
Calibration ManualDruck PACE Calibration Manual KE0450SpanishPDF下载
Calibration ManualDruck PACE Calibration Manual KF0450FrenchPDF下载
FlierDruck PACE Tallis NPI Aerospace FlyerEnglishPDF下载
FlierDruck PACE Tallis NPI Metrology FlyerEnglishPDF下载

联系我们

Druck 专家随时准备通过电子邮件、联系表单和电话为您提供咨询。


美国和加拿大:+1 346 330 1150
法国:+33 562 888 250
中国:+86 800 9159 966